Electrical Engineering and Systems Science > Signal Processing
arXiv:2512.15807 (eess)
Abstract:Epileptic seizures arise from abnormally synchronised neural activity and remain a major global health challenge, affecting more than 50 million people worldwide. Despite advances in pharmacological interventions, a significant proportion of patients continue to experience uncontrolled seizures, underscoring the need for alternative neuromodulation strategies. Rhythmic neural entrainment has recently emerged as a promising mechanism for disrupting pathological synchrony, but most existing systems rely on complex analogue electronics or high-power stimulation hardware. This study investigates a minimal digital custom-designed chip th…
Electrical Engineering and Systems Science > Signal Processing
arXiv:2512.15807 (eess)
Abstract:Epileptic seizures arise from abnormally synchronised neural activity and remain a major global health challenge, affecting more than 50 million people worldwide. Despite advances in pharmacological interventions, a significant proportion of patients continue to experience uncontrolled seizures, underscoring the need for alternative neuromodulation strategies. Rhythmic neural entrainment has recently emerged as a promising mechanism for disrupting pathological synchrony, but most existing systems rely on complex analogue electronics or high-power stimulation hardware. This study investigates a minimal digital custom-designed chip that generates a stable 6 Hz oscillation capable of entraining epileptic seizure activity. Using a publicly available EEG seizure dataset, we extracted and averaged analogue seizure waveforms, digitised them to emulate neural front-ends, and directly interfaced the digitised signals with digital output recordings acquired from the chip using a Saleae Logic analyser. The chip pulse train was resampled and low-pass-reconstructed to produce an analogue 6 Hz waveform, allowing direct comparison between seizure morphology, its digitised representation, and the entrained output. Frequency-domain and time-domain analyses demonstrate that the chip imposes a narrow-band 6 Hz rhythm that overrides the broadband spectral profile of seizure activity. These results provide a proof-of-concept for low-power digital custom-designed entrainment as a potential pathway toward simplified, wearable seizure-interruption devices for precision medicine and future healthcare devices.
| Comments: | precision healthcare, neuro technology, healthcare engineering (24 pages) |
| Subjects: | Signal Processing (eess.SP); Emerging Technologies (cs.ET) |
| Cite as: | arXiv:2512.15807 [eess.SP] |
| (or arXiv:2512.15807v1 [eess.SP] for this version) | |
| https://doi.org/10.48550/arXiv.2512.15807 arXiv-issued DOI via DataCite |
Submission history
From: Arfan Ghani [view email] [v1] Wed, 17 Dec 2025 05:07:17 UTC (1,354 KB)
Current browse context:
eess.SP
Change to browse by:
export BibTeX citation