Abstract:Alzheimer’s disease (AD) is an irreversible neurodegenerative disorder, and early diagnosis is critical for timely intervention. However, most existing classification frameworks face challenges in multicenter studies, as they often neglect inter-site heterogeneity and lack mechanisms to quantify uncertainty, which limits their robustness and clinical applicability. To address these issues, we proposed Uncertainty-Guided Federated Domain Adaptation (UG-FedDA), a novel multicenter AD classification framework that integrates uncertainty quantification (UQ) with federated domain adaptation to handle cross-site structure magnetic resonance imaging (MRI) heterogeneity under privacy constraints. Our approach extracts multi-templa…
Abstract:Alzheimer’s disease (AD) is an irreversible neurodegenerative disorder, and early diagnosis is critical for timely intervention. However, most existing classification frameworks face challenges in multicenter studies, as they often neglect inter-site heterogeneity and lack mechanisms to quantify uncertainty, which limits their robustness and clinical applicability. To address these issues, we proposed Uncertainty-Guided Federated Domain Adaptation (UG-FedDA), a novel multicenter AD classification framework that integrates uncertainty quantification (UQ) with federated domain adaptation to handle cross-site structure magnetic resonance imaging (MRI) heterogeneity under privacy constraints. Our approach extracts multi-template region-of-interest (RoI) features using a self-attention transformer, capturing both regional representations and their interactions. UQ is integrated to guide feature alignment, mitigating source-target distribution shifts by down-weighting uncertain samples. Experiments are conducted on three public datasets: the Alzheimer’s Disease Neuroimaging Initiative (ADNI), the Australian Imaging, Biomarkers and Lifestyle study (AIBL), and the Open Access Series of Imaging Studies (OASIS). UG-FedDA achieved consistent cross-domain improvements in accuracy, sensitivity, and area under the ROC curve across three classification tasks: AD vs. normal controls (NC), mild cognitive impairment (MCI) vs. AD, and NC vs. MCI. For NC vs. AD, UG-FedDA achieves accuracies of 90.54%, 89.04%, and 77.78% on ADNI, AIBL and OASIS datasets, respectively. For MCI vs. AD, accuracies are 80.20% (ADNI), 71.91% (AIBL), and 79.73% (OASIS). For NC vs. MCI, results are 76.87% (ADNI), 73.91% (AIBL), and 83.73% (OASIS). These results demonstrate that the proposed framework not only adapts efficiently across multiple sites but also preserves strict privacy.
| Comments: | The code is already available on GitHub: this https URL |
| Subjects: | Computer Vision and Pattern Recognition (cs.CV) |
| Cite as: | arXiv:2512.05814 [cs.CV] |
| (or arXiv:2512.05814v1 [cs.CV] for this version) | |
| https://doi.org/10.48550/arXiv.2512.05814 arXiv-issued DOI via DataCite (pending registration) |
Submission history
From: Chen Zhao [view email] [v1] Fri, 5 Dec 2025 15:33:52 UTC (3,375 KB)