Abstract:Deep learning (DL) has the potential to revolutionize image acquisition and interpretation across medicine, however, attention to data imbalance and missingness is required. Ultrasound data presents a particular challenge because in addition to different views and structures, it includes several sub-modalities-such as greyscale and color flow doppler (CFD)-that are often imbalanced in clinical studies. Image translation can help balance datasets but is challenging for ultrasound sub-modalities to date. Here, we present a generative method for ultrasound CFD-greyscale video translation, trained on 54,975 videos and tested on 8,368. The method developed leveraged pixel-wise, adversarial, and perceptual loses and utilized two ne…
Abstract:Deep learning (DL) has the potential to revolutionize image acquisition and interpretation across medicine, however, attention to data imbalance and missingness is required. Ultrasound data presents a particular challenge because in addition to different views and structures, it includes several sub-modalities-such as greyscale and color flow doppler (CFD)-that are often imbalanced in clinical studies. Image translation can help balance datasets but is challenging for ultrasound sub-modalities to date. Here, we present a generative method for ultrasound CFD-greyscale video translation, trained on 54,975 videos and tested on 8,368. The method developed leveraged pixel-wise, adversarial, and perceptual loses and utilized two networks: one for reconstructing anatomic structures and one for denoising to achieve realistic ultrasound imaging. Average pairwise SSIM between synthetic videos and ground truth was 0.91+/-0.04. Synthetic videos performed indistinguishably from real ones in DL classification and segmentation tasks and when evaluated by blinded clinical experts: F1 score was 0.9 for real and 0.89 for synthetic videos; Dice score between real and synthetic segmentation was 0.97. Overall clinician accuracy in distinguishing real vs synthetic videos was 54+/-6% (42-61%), indicating realistic synthetic videos. Although trained only on heart videos, the model worked well on ultrasound spanning several clinical domains (average SSIM 0.91+/-0.05), demonstrating foundational abilities. Together, these data expand the utility of retrospectively collected imaging and augment the dataset design toolbox for medical imaging.
| Subjects: | Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI) |
| Cite as: | arXiv:2511.03255 [cs.CV] |
| (or arXiv:2511.03255v1 [cs.CV] for this version) | |
| https://doi.org/10.48550/arXiv.2511.03255 arXiv-issued DOI via DataCite (pending registration) |
Submission history
From: Rima Arnaout [view email] [v1] Wed, 5 Nov 2025 07:32:43 UTC (8,763 KB)